FAULHABER Announces Sterilizable Drive Solution

Peak Performance for Surgical Handheld Devices
High speeds, high torque, minimal vibration and repeated sterilization cycles: the next generation of surgical handheld devices requires drive systems that combine uncompromising performance with the highest standards of sterility. With the new autoclavable platform, FAULHABER offers a powerful drive solution consisting of motors from the BHx A family, the 16GPS A planetary gearhead and the IEM3 A encoder. This compact platform solution combines high performance, robustness and flexibility.
Maximum Performance for Surgical Applications
The new platform is based on the brushless 1645 BHSA, 1660 BHSA and 1660 BHTA motors. While the BHSA variants are optimized for high-speed applications, the BHTA version has been specifically developed for applications requiring particularly high torque. Combined with the 16GPS A planetary gearhead, they form a powerful drive system for sophisticated surgical instruments. The gearhead features a specially developed architecture with a robust design and offers reduction ratios of up to 50:1. For precise position and speed feedback, the IEM3-1024 A and IEM3-1024 LA encoder variants are available. The perfectly matched components ensure excellent control performance and support smooth operation with low vibration levels, which is particularly important for sensitive medical procedures.
Designed for Sterilization and Long Service Life
A key advantage of this system solution is its suitability for sterilization and disinfection processes. Medical instruments are routinely autoclaved and must maintain their performance reliably even after numerous reprocessing cycles. The drive components have therefore been specifically designed for use under these conditions and can withstand more than 1,000 autoclave cycles. The robust, intrinsically autoclavable component-level design eliminates the need for protection-based solutions such as potting on the outer motor surface, thereby enhancing resistance to saturated steam environments and repeated sterilization cycles. At the same time, a comparatively low surface temperature, high output power and the reliability required for medical applications contribute to the long-term and sustainable use of the devices. The components have also undergone extensive validation and qualification processes to meet the stringent requirements of the medical technology industry.
In addition, the platform offers a wide range of customization options. Mechanical and electrical interfaces can be adapted to specific device concepts. Additional features, such as the integration of thermal sensors or sealing solutions, enable further optimization to meet individual application requirements.
Source: FAULHABER